问题 #1
Which of the following descriptions about data center monitoring systems is wrong?
A. Can monitor power system, environmental system, fire protection system, etc.
B. Remote monitoring is not supportedcorrect
C. Can provide multiple alarm methods such as voice and short message
D. Intelligent monitoring system can improve management efficiency
正确答案:B
问题 #2
If the capacity of UPS is 20KVA, then in normal operation, the UPS front-end input capacity may be ()
A. 25KVAcorrect
B. 30KVA
C. 28KVA
正确答案:A
问题 #3
Which of the following statements about condensers is wrong?
A. Under normal circumstances, the inlet temperature of the condenser in an air-cooled direct expansion air conditioner is higher than the outdoor temperature.
B. Condensers can be divided into air-cooled condensers and water-cooled condensers.
C. Condensation water will be generated when indoor air passes through the surface of the condenser.correct
D. The condenser of an air-cooled direct expansion air conditioner is generally installed outdoors.
正确答案:C
问题 #4
Data center energy consumption mainly comes from the ring equipment, lighting system, refrigeration systems, power supply and distribution system. How to reduce the energy dissipations of the ( ) is the key to solve data center energy conservation in the industry at present.
A. IT equipment
B. Refrigeration system
C. Lighting System
D. Power Supply and Distribution System
正确答案:B
问题 #5
UPS The front-end input can be two mains, one main and one standby, or one mains and one diesel engine input.
A. Truecorrect
B. False
正确答案:A
问题 #6
Which of the following components can check whether the refrigerant contains moisture?
A. Solenoid valve
B. Sight glasscorrect
C. Filter drier
D. Oil sight glass
正确答案:B
问题 #7
There are generally two types of variable air volume ventilated floors, one is through an adjustable air valve, and the other is a dedicated ventilated floor plus adjustable fans.
A. Truecorrect
B. False
正确答案:A
问题 #8
The access control system can only set the user to open the door, and cannot set when to open the door.
A. True
B. Falsecorrect
正确答案:B
问题 #9
In Main Inverter mode, the UPS will switch from Main Inverter mode to Static Bypass mode when mains input voltage and frequency exceed the allowable range of the UPS.
A. TRUE
B. FALSE
正确答案:B
问题 #10
The active power is 80 kW, the power factor is 0.8, the system rated voltage is 380 V, 50 Hz, what is the current when the equipment is running at full power?
A. 122 A
B. 152 Acorrect
C. 210 A
D. 263 A
正确答案:B
问题 #11
Which of the following descriptions about electrical equipment safety is wrong?
A. The metal casing of electrical equipment must be grounded (zeroed) for protection
B. Electrical equipment should be corrosion-resistant and moisture-proof
C. When a fire occurs in electrical equipment, water can be used to extinguish the fire.correct
D. It is strictly forbidden to use electrical equipment beyond the rated value
正确答案:C
问题 #12
For the unsaturated air, the relationship of size among the dry bulb temperature, wet bulb temperature and dew point temperature is ().
A. Wet bulb temperature> dew point temperature> dry bulb temperature
B. Dry bulb temperature> Dew point temperature> Wet bulb temperature
C. wet bulb temperature> dry bulb temperature> dew point temperature
D. Dry bulb temperature> wet bulb temperature> dew point temperature
正确答案:D
问题 #13
The gas fire extinguishing system consists of ()
A. Fire extinguisher storage bottle set, starting device, fire pipe network, sprinklercorrect
B. No other options
正确答案:A
问题 #14
Which of the following functions uses electronic tag technology to provide real-time statistics on the location of power distribution, air conditioning, refrigeration and other infrastructure?
A. Operation and maintenance management
B. Asset Managementcorrect
C. Report Management
D. System Management
正确答案:B
问题 #15
ATS The dual power supply automatic switch can realize the fast mechanical switching of the two power supplies.
A. True
B. False
正确答案:A
问题 #16
The increase of cabinet power density will lead to the emergence of local hot spots in the computer room, and row-level air conditioners can solve local problems. The hot spot is too high.
A. Truecorrect
B. False
正确答案:A
问题 #17
In the low-voltage power distribution system, N The role of the wire is to return the AC operating current.
A. Truecorrect
B. False
正确答案:A
问题 #18
What is used to indicate the severity of the corresponding fault in dynamic environment monitoring system?
A. Alarm time
B. Alarm name
C. Alarm level
D. Alarm source
正确答案:C
问题 #19
MCB circuit breakers can be divided into B, C, D, Z, and K levels according to different tripping characteristics. Which level of tripping characteristics should be used for IT loads?
A. B level
B. C-levelcorrect
C. D level
D. Z level
正确答案:B
问题 #20
Which of the following belongs to air - cooled line air conditioning?
A. NetCol5000 - C
B. NetCol5000 - A
C. NetCol8000 - C
D. NetCol8000 - A
正确答案:B
问题 #21
Which of the following devices can be used to store video recordings for a long time?
A. UPS
B. NVRcorrect
C. AC Actuator
D. Switch
正确答案:B
问题 #22
Regarding the description of the data center cooling system, which of the following is wrong?
A. Among rack-level, row-level and room-level cooling, row-level cooling has the shortest airflow path.correct
B. No other options
正确答案:A
问题 #23
Which of the following is the maximum communication distance of RS485 communication method?
A. 5 m
B. 100 m
C. 15 m
D. 1200 mcorrect
正确答案:D
问题 #24
R410a Refrigerants can produce the greenhouse effect and destroy the ozone layer.
A. True
B. Falsecorrect
正确答案:B
问题 #25
PLE Defined as the power consumption of the data center power supply and distribution system and IT The ratio of the power consumption of the device.
A. False
B. True
正确答案:B
问题 #26
In an air conditioning system, which of the following uses water cooling or air cooling to cool the high-temperature and high-pressure gas discharged from the compressor and release the heat to the outside?
A. Evaporator
B. Condensercorrect
C. Compressor
D. Expansion valve
正确答案:B
问题 #27
According to the concentration degree of equipment, air conditioning system can be divided into ( ). (Multiple choice)
A. Mixed
B. Semi-centralized
C. decentralized
D. Centralized
正确答案:BCD
问题 #28
ATS Dual Power Automatic Transfer Switch can achieve the switching of two - way power's fast loading machine.
A. True
B. False
正确答案:A